Automatic wire tier is missing on one side.
Machines operates in manual mode only, operator must remain in contact with switch while in operation
Tested and works as it should in manual mode wired, 480V
Machine will work as is, but must be manually tied, or run continuously without ties.
Unit will need evaluated and programmed to utilize PLC and monitor
Upgrades were utilized but look as though they were later abandoned. There is a PLC and Touch screen added that do not communicate.
We had a professional technician come out and evaluate machine, eliminate abandoned wiring and give an overall review of equipment.
The compactor tunnel is 13' x 30" (not compacted sides) 24" compacted sides x 36" tall
Bale size is approx. 24" w x 36" t x 48" l
Appears many hydraulics are newer. The pump appears newer, hoses, valves etc.
Tank measures 33" x 55" x17" (usable level) 24" topped off level Approx. 89 Gallon full capacity and 125 gallon total capacity
Ram cylinder is 8" bore x 44" stroke
Pump motor is Elektrim 50Hp 230/460V 113/56.5A
Top load chute measures 28-1/2" Square, flange outside measures 33" Square